Products
Contact Us
Guangzhou Baicheng Air Conditioning Equipment Co., Ltd
Telephone:020-32144098
Fax: 020-32146966
Website:www.gzbc.net
Address: No. 5, Xinhe South Road, Zengcheng Economic and Technological Development Zone, Guangzhou
Zip Code: 511300
GDF type centrifugal duct fan
Classification:
The company mainly produces 5N, 5N5-6N5 ultra-high purity aluminum and aluminum alloy materials, of which 6N5 ultra-high purity aluminum is the exclusive research and development and normal production in the country. The company has an annual production capacity of 1200 tons of high-purity aluminum, and can provide φ30-φ450mm, 1070 × 380mm and other specifications of round, flat ingots, profiles and other high-purity aluminum and alloy ingots, targets, profiles, etc. according to customer requirements.
Key words:
Consulting:
Product Description
GDF series centrifugal pipe fan is a new product developed independently on the basis of absorbing foreign advanced technology. The product has high static pressure, stable rotation, low noise and small installation size. Easy to install, can be directly connected with the air duct. The fan can be widely used in hotels, shopping malls, hospitals, theaters, dance halls, auditoriums, colleges and universities and scientific research units, as well as industrial and civil buildings in the ventilation.
This series of products according to the impeller diameter is divided into 3#, 3.5#, 4#, 5#, 5.6#, 6#, 7#, 8#, 9#, 10#
Structure of fan
The impeller is made of galvanized steel sheet and consists of a front plate, a rear plate and a plurality of forward arc-shaped blades. Parts are made of mechanized mold. After static and dynamic balance check, the operation is stable and reliable, with good aerodynamic performance.
The casing is made of galvanized steel plate, which is connected by spot welding after mechanization and mold processing. The structure is firm, reasonable and compact. ● The motor support is made of galvanized steel sheet and formed by mechanized mold.
The motor adopts a single-support external rotating motor, the impeller is fixed on the motor shell, the motor support end is fixed on the motor support, the motor support is fixed on the top plate of the casing, and the motor shell rotates directly to drive the impeller to run.
Conditions of use of fan
Types of gas delivery: air and other non-spontaneous combustion, non-corrosive, harmless to the human body gas.
Impurities in the gas: no viscous substances are allowed in the gas, and the dust and hard particles contained in the gas are not more than 120 mg/m.3. Gas temperature range:-20 ° C ~ 60 ° C.
This series of fans are only suitable for indoor installation, and should be installed horizontally or vertically according to the pattern orientation in the "Design Selection Instructions. If you need to be outdoors, you must consider the rain-proof measures of the motor. Ensure that the fan room is equipped with drainage.
All fans are standard. That is, single-phase 220V/50Hz, three-phase 220V/380V, 50Hz.
Design Selection Description
The duct fan is a forward multi-airfoil centrifugal fan, and its noise is much lower than that of the axial fan under the same air volume and air pressure. The air volume, pressure, noise and other parameters of this series of fans are put forward according to the actual needs of many projects, and are widely used in the air supply and exhaust systems in public places.
The top surface of the fan shell is marked with an arrow of the air outlet direction, which can avoid reverse installation and ensure the normal use of the air supply and exhaust system.
When the conveyed low-temperature air may cause condensation on the outer surface of the casing and pipe, the insulation layer shall be designed.
The noise of the fan is the average value measured at one meter away from the air inlet when the rated air volume and air pressure are not connected to the air duct. If equipped with inlet and exhaust ducts, the noise will be attenuated. For occasions with high noise requirements, muffler elbows or mufflers should be configured on the inlet and exhaust ducts.
The power wiring diagram of the fan equipped motor is placed on the side of the fan power junction box.
Fan running vibration is very small, generally do not need to take measures to reduce vibration. If necessary in the design, damping rubber pads or damping springs can be added at the fan support.
When installing the fan, the distance between the fan and the top of the floor must be considered to facilitate the disassembly during maintenance.
Scope of application
Guesthouse |
Hotel |
Canteen |
Kitchen |
Related Products
Product Message
Focus on us
Pay attention to WeChat public number
Guangzhou Baicheng Air Conditioning Equipment Co., Ltd
Telephone:020-32144098
Fax: 020-32146966
Website:www.baichengfan.com.cn
Address: No. 5, Xinhe South Road, Zengcheng Economic and Technological Development Zone, Guangzhou
Zip Code: 511300
copyright?2023 Guangzhou Baicheng Air Conditioning Equipment Co., Ltd. | Business License